Class 4
Understanding Arc Flash — ARC 4
Class 4 Arc Protection: 40+ cal/cm²
ARC 4 is the highest tier of Arc Flash protection ProGARM offers, built for the small number of tasks where incident energy can exceed 40 cal/cm² — high-voltage switching, racking, and work inside enclosed switchgear. At this level, the margin for error in PPE selection disappears.
What does ARC 4 mean?
ProGARM uses ARC 1 to ARC 4 to describe ELIM ratings from the Open Arc Test (IEC 61482-1-1) — the highest incident energy a garment can withstand with a 0% probability of injury. ARC 4 covers 40+ cal/cm², the top of the scale, and typically corresponds to an APC 2 classification (passing the Box Test at 7kA / 320 kJ). This is the tier reserved for switching operations and high-energy tasks — where a lower-rated garment would leave a dangerous gap between what the PPE can absorb and what a real arc fault could deliver.
For the full breakdown of how ARC ratings, ELIM, ATPV, EBT50 and APC classifications are calculated, see ProGARM’s guide to Arc Risk Category Levels.
ARC tiers at a glance
| Tier | ELIM Range | Typical Use |
|---|---|---|
| ARC 1 | 4–7 cal/cm² | Low voltage work, layered systems, baselayers |
| ARC 2 | 8–25 cal/cm² | Standard outerwear for routine maintenance and switching |
| ARC 3 | 25–39 cal/cm² | Outerwear for elevated incident energy environments |
| ARC 4 | 40+ cal/cm² | High-voltage switching — Arc 4 Switching Suit with PYRAD® Technology, APC 2 |
Who needs ARC 4 protection?
The right ARC tier for any task is set by a documented arc flash risk assessment, not by job title alone — but ARC 4 is most commonly specified for:
- Switching and racking operations on live LV/MV/HV switchgear
- Work inside enclosed panels and cabinets where fault current is high
- Substation maintenance in industrial electrical and power generation environments
- High-voltage battery and charging infrastructure work in the electric vehicle sector
- Rail traction and signalling teams working near high-energy equipment
If you haven’t yet completed an arc flash study for these tasks, ProGARM’s specialists can help you scope one — speak to a specialist.
The ProGARM Arc 4 Switching Suit
ProGARM’s ARC 4 range is built around the Arc 4 Switching Suit with PYRAD® Technology by GORE-TEX LABS — the first suit of its kind available in the UK, and a genuine step-change from traditional bulky Arc 4 protection. Where older ARC 4 garments relied on heavy multi-layer construction to hit 40 cal/cm², PYRAD® achieves the same ELIM 40 cal/cm² rating (APC 2) in a lightweight, single-ply laminate.
Up to 20%
Lighter than competitive premium products
Up to 48%
Thinner than competitive premium solutions
Up to 64%
More flexible for easier movement
The PYRAD® membrane is a 3-layer laminate engineered into a single ply. During an arc event, it blocks heat flow and forms a carbonaceous char with the fabric, reducing heat transfer to the skin — without the bulk of a traditional multi-layer ARC 4 system. The result is a suit that reduces muscular fatigue during repetitive tasks like rack removal and winding, with an advanced moisture management system that keeps wearers cooler and drier through a full shift. Full range detail is on the GORE-TEX® PYRAD collection page.
Build your Arc 4 kit
The Arc 4 Switching Suit is a complete system — jacket, dungaree, hood and gloves — each independently tested and rated to work together at ELIM 40 cal/cm² (APC 2). Available in 54 size combinations across male and female specific fits, short, regular and tall lengths.
Certified across three European standards
Every component of the Arc 4 Switching Suit is independently tested and certified — not just the fabric, but the seams, closures and the complete garment assembly:
This means the Arc 4 Switching Suit isn’t just Arc Flash rated — it’s a genuine multi-norm garment, combining arc, thermal and anti-static protection for teams working in explosive-atmosphere-adjacent environments alongside high-energy switching risk. It’s backed by ProGARM’s Lifetime Seam Guarantee, and every garment is fitted with ThermSAFE fastenings — zips, poppers and Velcro engineered from military-grade, non-spark FR materials that keep functioning after an arc event.
Choosing the right level for your team
ARC 4 is not a default choice — it’s a specific answer to a specific calculated risk. Before specifying the Arc 4 Switching Suit:
- Identify the task and incident energy using your arc flash study or a documented risk assessment at the working distance.
- Confirm the incident energy exceeds 40 cal/cm², or that switchgear working practices otherwise require APC 2 confined-arc protection.
- Fit the complete system — jacket, dungaree, hood and gloves — rather than mixing an ARC 4 outer layer with lower-rated accessories.
If you haven’t completed a risk assessment, or you’re unsure whether your team’s tasks call for ARC 3 or ARC 4 protection, ProGARM’s specialists can help. Request a quote or speak to a specialist today.
Ready to specify ARC 4 protection?
Speak to ProGARM’s specialist team about the Arc 4 Switching Suit, sizing, bulk orders, or custom branding for your team.
Request a Quote View GORE-TEX® CollectionRelated resources
- Arc Risk Category Levels — full guide to ARC 1–4, ELIM, ATPV, EBT50 and APC classifications
- EN Standards & Certifications — every standard ProGARM garments are tested to
- Industrial Electrical PPE — sector guidance for switching and substation work
- In-House Testing Laboratory — how ProGARM verifies every garment before certification
- Arc Flash FAQs — common questions on ratings, care and compliance